MULTI-PARAMETER PATIENT SIMULATOR PS-2110 USER MANUAL
2 PACEMAKER FUNCTION A pacemaker waveform may be simulated. WAVEFORM: ASYNCHRONOUS PULSE HEIGHT: 1.0 mV PULSE WIDTH: 1.0
3 RESPIRATION Respiration is simulated at 8 different rates plus apnea, with the ability to select from 2 Baseline Impedances, the Lead in which it
4 SPO2 SIMULATION (Option) When used with the MSP-2100 external module and FingerSim family of SpO2 finger simulators, the system will provide a pu
5 This section looks at the layout of a PS-2110 and gives descriptions of the elements that are present. 4 Light
6 General Operation The unit is controlled by 13 light touch keys. They allow the user to move around within the displayed parameters, select the d
7 The key opens a screen that allows the user to select the unit’s general output settings, as well as setup for the system. Category K
8 Backlight The Graphic LCD display may be viewed with or without the backlight. Depressing any key will activate the backlight. However, since th
9 Respiration Respiration waveforms are provided that have adjustable rates from 15 to 120 BrPM (Breaths Per Minute) as well as an Apnea (0 BrPM) se
10 Universal Patient Lead Connectors The 10 Universal Patent Lead Connectors allow for 12 lead ECG simulation with independent outputs.
11 Auto Power Off The unit may be programmed to automatically turn off after a selected number of minutes of no key activity to conserve the battery
12 Automatic Modes The ECG NSR Rate, ECG Performance and Static Blood Pressure Parameters all allow for an automatic setting. In each of these, t
13 The PS-2110 can send NSR waveforms to ECG machines in 3, 5 or 12 lead configurations. It has independent outputs for each signal l
14 Alternately, to see a submenu of all the options for a highlighted parameter, use . Use to scroll to the desired o
15 The PS-2110 can send arrhythmia waveforms to ECG machines in 3, 5 or 12 lead configurations. It has independent outputs for each
16 The arrhythmias and amplitude can be selected by using to highlight the parameter to change and using
17 The following is a brief description of how the PS-2110 simulates the available Arrhythmias: Abbreviation Arrhythmia Description At
18 Multifocal PVCS – Auto Multifocal Premature Ventricular Contraction NSR of 80 BPM with Type 1 and Type 2 PVCs (PVC Type 1, 2 NSR, PVC TYPE
19 The PS-2110 can send performance waveforms to ECG machines in 3, 5 or 12 lead configurations. It has independent outputs for each signal lead, r
20 Alternately, to see a submenu of all the options for a highlighted parameter, use . Use to scroll to the desir
21 NOTE: The Transducer Sensitivity (5 uV/V/mmHg or 40 uV/V/mmHg) must be set to correlate with the monitoring equipment before simulation can be
i WARNINGS, CAUTIONS, NOTICES ... ii DESCRIPTION ...
22 These settings can be selected by using to highlight the parameter to change and using t
23 NOTE: The delta ohm Respiration Signal can be inserted in either the LL or LA lead. The Baseline impedance can be set to either 500 or 100
24 These rates and Impedance Variations can be selected by using to highlight the parameter to change and using
25 The PS-2110 simulates 3 temperatures that are independent from the rest of the functions of the unit. The temperature setting can be selected a
26 The PS-2110 allows for setup of the Outputs and the System Parameters through the category key. Depressing the key multiple times to
27 System Setup The System Setup screen allows for the setting of the parameters controlling various function of the unit as well as the viewing of
28 The following is a brief description of the parameters and the available range of settings: Parameter Description Range Auto Off Timer The e
29 The PS-2110 allows the user to tailor the settings that the unit will have on Power Up. The “Power Up With” parameter in the System Setup Menu
30 Last If this option is selected, the unit will remember the settings that were being used when it was turned off and bring them back when the pow
31 The PS-2110 has the ability to drive an external SpO2 module. This module (MSP-2100) accepts the FingerSim family of SpO2 finger simulators (fi
ii WARNING - USERS The PS-2110 is for use by skilled technical personnel only. WARNING - USE The PS-2110 is intended for
32 The following are representations of the socket connectors found on the unit. They are viewed as if looking at the socket in the unit, not the
33 Revision # Program # Revisions Made Rev 01 DT7346 Origination Rev 02 DT7346 Misc. Edits Rev 03 DT7346 Misc. Edits Rev 04 DT7346 Over
34 ECG SIMULATION RATE NORMAL SINUS RHYTHM 30, 60, 80, 120, 180, 240, 300 BPM PERFORMANCE WAVEFORMS SINE 0.1, 0.5, 5, 10, 40, 50, 60, 100 Hz SQUA
35 PHYSICAL & ENVIRONMENTAL DISPLAY 128 X 64 Pixels Graphical LCD, White LED Backlight CONSTRUCTION ENCLOSURE ABS Plastic FACE PLATE Lexan, Back
36 NOTES
37 NOTES
38 NOTES
BC GROUP INTERNATIONAL, INC. 3081 ELM POINT INDUSTRIAL DRIVE ST. CHARLES, MO 63301 USA 1-800-242-8428 1-314-638-3800 www.bcgroup
iii CAUTION - ENVIRONMENT Exposure to environmental conditions outside the specifications can adversely affect the performance of the PS-2110. Allow
iv NOTICE – CE The PS-2000 Series Meters bear the mark Based on the following testing standards: ELECTROMAGNETIC COMPATIBILITY DIRE
v NOTICE – SYMBOLS Symbol Description Caution (Consult Manual for Further Information) Center Negative Per European Council Directive
vi PS-2110 User Manual Copyright © 2012 www.bcgroupintl.com Made in the USA 10/12
1 The Model PS-2110 is a Microprocessor based Patient Simulator. It provides ECG, Blood Pressure, Respiration and Temperature Simulation.